The term "surface-watertight” means that the manhole cover is protected against the ingress of natural precipitation such as rain or other surface water that occurs without pressure.
Attack-proof and weatherproof manhole cover SD7.R, for flush fitting, load bearing, security tested, round type
Designed for
The cover is installed flush with the surface to accommodate pedestrian and/or vehicle traffic, with optional load classes A15, B125, D400, or E600. It is weatherproof, odor-tight against pressureless water, attack-proof, and round in shape. Constructed from 1.4307 (AISI 304 L) stainless steel, it offers durability and resistance to corrosion.
Secure to prevent forced access, certified to resistance class RC3 according to DIN EN 1627 in class D400, meeting the requirements of DVGW W 1050 - Object protection for water supply structures. Suitable for use in Ex zone 1.
Not suitable for high-volume traffic (See definition below at the Download section).
Designed for a clear width up to and including 3.2 ft. / 1000 mm and certified to:
DIN 1229 / DIN EN 124-1:2015-09 and DIN EN 124-3:2015-09, classes A15, B125, D400, E600 with test certificate and external monitoring
Designed for a clear width bigger than 3.2 ft. / 1000 mm and statically calculated according to:
DIN EN 1991:2010-12 (Eurocode 1) and DIN EN 1993:2010-12 (Eurocode 3), class EC10 (comparable with class A) and EC100 (comparable with class D)
Options
- 1.4404 (AISI 316 L) stainless steel
- Lift-off cover (without spring dampers and hinges)
- Non-standard sizes
- Encasing frame, non-standard installation height
- Designed for dowelling (only possible for class A15)
- The cover is designed with the option to be opened from below, ensuring practicality and safety. The traffic situation must be carefully considered during installation and operation to maintain compliance with safety and functional requirements
- Multi-part cover
- Suitable for high-volume traffic up to a maximum surface of 10.7 sq. ft. / 1 m² (no emergency exit possible). (See definition for high-volume traffic below in the Download section)
- Magnetic contact
- Cover insulation
- One-part covers watertight up to 15 ft. / 5m WC (class D400 only)
- One-part covers back-water proof up to 15 ft. / 5 m WC (class D400 only)
- Safety guard / anti-fall guard
Downloads
Customer Information and Documents
FAQ